Introduction
SZL/SZW series boilers are double-drum water-tube packaged boilers fitted with either chain grates or reciprocating grates.
This boiler adopts an assembled structure, split into two major sections: the upper section contains boiler heating surfaces, while the lower section houses combustion equipment. Two drums are arranged longitudinally along the boiler centerline. The front section of the upper drum, together with water-cooled wall tubes on both sides, forms the furnace’s radiant heating surface. The tube bundle between the rear section of the upper drum and lower drum serves as the convective heating surface. An economizer is installed at the boiler tail.
High-temperature flue gas produced from furnace combustion releases part of its heat first, then flows into the convective heating surface via the cooling chamber for further heat exchange. Afterwards, the flue gas passes through the economizer and dust collector, before being exhausted to the chimney by the induced draft fan.

SZL SZW Biomass Coal-Fired Boiler System Diagram

Advantages
The large furnace and spacious combustion chamber prolong fuel residence time. Staged air distribution and staged combustion enable thorough fuel‑oxygen mixing for better burnout, while controlling combustion temperature to prevent slagging.
The adoption of membrane water-cooled walls and water-cooled arch structures reduces air leakage rate and heat dissipation, extending the service life of the furnace arches.
Based on the characteristics of biomass fuels, appropriate feeding methods and arch design are implemented to prevent back-fire.
The rationally configured soot blowing device enables online cleaning, preventing ash accumulation on heating surfaces.
Equipped with well-planned ash cleaning doors and ash discharge doors, the boiler facilitates inspection and routine maintenance.
Customized feeding system, combustion system, slag discharge system, water treatment system,flue gas treatment system and boiler room layout.
Parameters
| SZL/SZW Series Steam Boiler Technical Parameter Table | ||||||||||
| Parameters | Model | SZL6 SZW6 | SZL8 SZW8 | SZL10 SZW10 | SZL12 SZW12 | SZL15 SZW15 | SZL20 SZW20 | SZL25 SZW25 | SZL30 SZW30 | SZL35 SZW35 |
| Rated steam capacity | T/h | 6 | 8 | 10 | 12 | 15 | 20 | 25 | 30 | 35 |
| Rated steam pressure | MPa | 1.25 1.6/2.5/3.82 | ||||||||
| Rated steam temperature | °C | 194/204/226/450 | ||||||||
| Feed water temperature | °C | 20/104 | ||||||||
| Thermal efficiency | % | ≥87 | ||||||||
| Exhaust gas temperature | °C | <130 | ||||||||
| Applicable fuel types | Class II bituminous coal, biomass fuels (wood, rice husk, Palm kernel shell, and the other) | |||||||||
Application
For saturated steam, superheated steam or hot water supply, in food, beverage, refining, petrochemical, pulp and paper, mining, manufacturing, utilities and other industries.